[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [Diffserv] I-D ACTION:draft-ietf-diffserv-mib-01.txt
I thought we'd agreed that token bucket parameters would be defined in terms
of rate and bucket size rather than interval and bucket size?
diffServTBMeterEntry OBJECT-TYPE
SYNTAX DiffServTBMeterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the meter table describes a single token
bucket meter. Note that a meter has exactly one rate,
defined as the burst size each time interval. Multiple
meters may be cascaded should a multi-rate token bucket
be needed in a given Per-Hop Behavior. An example of
such a PHB is AF."
INDEX { ifIndex, diffServInterfaceDirection,
diffServTBMeterNumber }
::= { diffServTBMeterTable 1 }
DiffServTBMeterEntry ::= SEQUENCE {
diffServTBMeterNumber INTEGER,
diffServTBMeterInterval Unsigned32,
diffServTBMeterBurstSize Unsigned32,
diffServTBMeterFailNext RowPointer,
diffServTBMeterSucceedNext RowPointer,
diffServTBMeterStatus RowStatus
_______________________________________________